575
[DC2+PK] UID return request (ISO/IEC15693) (CL4NX Only)
Command DC2 PK Parameter
Hexadecimal code <12>
16
<50>
16
<4B>
16
None
Initial value None
When turning off the power -
Valid range -
Printer operation in
progress
The command cannot be received during the printer
operation. ([NAK] return)
Valid range and term of
command
Error Commands can be received even if an error is occurring.
[Function]
Returns the status of RFID tag write by <RK> command and UID.
[Format]
[DC2]PK
[[DC2]PK return data format (normal)]
[STX]a…a,b,c,d…d[CR][LF][ETX]
[Return data]
Symbol Parameter name Valid range
a Total number of data byte
* This is the total number of bytes after
parameter b. The delimiting comma between
parameters a and b, and the ETX are not
included.
Data size from the first write result status until
before [ETX]
Maximum 5 digits
b Write result status 0: Write failure
1: Write success
* Specified in text format.
c Error symbol N: No error
U: UID read error
A: All errors
* Specified in text format.
d UID return data Refer to [UID return data] as below.
* Specified in text format.
[Format of UID return data]
"Specify memory" +
":"+"Data"
+ "Line feed(0DH,0AH)"
ee:f…f[CR][LF]