319
[ESC+QV] QR code version
ESC QV ParameterHexadecimal code
<1B>
16
<51>
16
<56>
16
aa
Initial value aa=00
When the power is OFF The set parameter is not maintained.
Valid range within items The set parameter is in effect until a new specification is
made.
Valid range and term of
command
Valid range between items The set parameter becomes a default value in the next
item <A>.
[Function]
Specifying any QR code version can print the code with fixed cell size.
When not specified, it becomes the auto setting.
[Format]
<QV>aa
• Parameter
a [Version number]
     
Valid range
 
:
 
00 to 40
      
(Specifying this range does not become a parameter error.
      
An error may arise for some QR code types, while analyzing the image.)
 
     
Print valid
 
MODE1
 
:
 
00 to 14 (00: Auto setting)
           
MODE2
 
:
 
00 to 40 (00: Auto setting)
           
MicroQR
 
:
 
00 to 04 (M1 to M4) (00: Auto setting)
[Coding Example 1]
MODEL 1, Error correction: H, Cell size font: 05, Manual setting, Normal mode, Version 14
<A>
<V>100<H>100 <2D31>,H,05,0,0
<QV>14
<DN>0011,0123456789X
<Q>1
<Z>
[Coding Example 2]
MODEL 2, Error correction: H, Cell size font: 05, Manual setting, Normal mode, Version 35
<A>
<V>100<H>100 <2D30>,H,05,0,0
<QV>35
<DN>0011,0123456789X
<Q>1
<Z>