EasyManua.ls Logo

SATO CL6NX - [ESC+CL] Delete CR;LF

SATO CL6NX
756 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
363
[ESC+CL] Delete CR/LF
ESC CL ParameterHexadecimal code
<1B>
16
<43>
16
<4C>
16
a
Initial value Nil
When the power is OFF The set parameter is maintained.
Valid range within items The set parameter is valid until the next valid setting.
Valid range and term of
command
Valid range between items The set parameter is valid until the next valid setting.
[Function]
Deletes CR/LF included in print commands.
[Format]
<CL>a
• Parameter
a [Delete CR/LF]
     
0
 
:
 
Do not delete CR/LF
     
1
 
:
 
Deletes CR/LF
[Coding Example]
<A>
<CL>1
<Z>
[Supplementary Explanation]
• Delimit Start of Data Transmission <A> and End of Data Transmission <Z> with this command
for use.
• This command cannot be used in combination with other commands.
Parent topic System Command

Table of Contents

Other manuals for SATO CL6NX

Related product manuals