405
[ESC+BJT] TrueType Font Call (Compatible command)
ESC BJT ParameterHexadecimal code
<1B>
16
<42>
16
<4A>
16
<54>
16
,aa,bb,cc,dd,ee,ffff,n...n
Initial Value Nil
When the power is OFF The set parameter is not maintained.
Valid range within items The set parameter becomes invalid.
Valid range and term of
command
Valid range between items The set parameter becomes invalid.
[Function]
Specifying TrueType Font call.
[Format]
<BJT>,aa,bb,cc,dd,ee,ffff,n...n
• Parameter
a [Font ID] Valid Range : 00 to 99
b [Horizontal scale factor] Valid Range : 01 to 12
c [Vertical scale factor] Valid Range : 01 to 12
d [Word Pitch] Valid Range : 00 to 99
e [Reserve] Valid Range : 00 (Fixed)
f [Reserve] Valid Range : 0000 (Fixed)
n [Data]
[Coding Example]
<A>
<V>100<H>200<CC>1
<BJT>,01,02,02,01,00,0004SATO
<Q>
<Z>
[Supplementary Explanation]
• Specify slot number of Card Slot for Use <CC> prior to this command when using.
[Note]
• Do not turn the printer's power off when accessing to the memory. When the printer power is off
while memory accessing, the data in the accessed media may be corrupted.
• This is the command of the old specification. Recommend the use of [DC2]DE and <RH>.