EasyManua.ls Logo

SATO CL6NX - [DC2+PK] IDM Return (Felica) (CL4 NX Only)

SATO CL6NX
756 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
589
[DC2+PK] IDm return (FeliCa) (CL4NX Only)
Command DC2 PK Parameter
Hexadecimal code <12>
16
<50>
16
<4B>
16
None
Initial value None
When turning off the power -
Valid range -
Printer operation in
progress
The command cannot be received during the printer
operation. ([NAK] return)
Valid range and term of
command
Error Commands can be received even if an error is occurring.
[Function]
Returns the result of writing to RFID tag using <RK> command together with a 64-digit hexadecimal
numeric sequence as a result of IDm+PMm+ID block.
[Format]
[DC2]PK
[[DC2]PK return data format (normal)]
[STX]a…a,b,c,d…d[CR][LF][ETX]
[Return data]
Symbol Parameter name Valid range
a Total number of data byte
*
This is the total number of bytes after
parameter b. The delimiting comma between
parameters a and b, and the ETX are not
included.
Data size from the first write result status until
before [ETX]
Maximum 5 digits
b Write result status 0: Write failure
1: Write success
* Specified in text format.
c Error symbol N: No error
I: IDm read error
A: All errors
* Specified in text format.
d IDm return data Refer to [IDm return data] as below.
* Specified in text format.
[Format of IDm return data]
"Specify memory" + ":" + "Data" + "Line feed(0DH,0AH)"
ee:f…f[CR][LF]