380
[ESC+YS] Format Registration
ESC YS ParameterHexadecimal code
<1B>
16
<59>
16
<53>
16
,aaa
Initial value Nil
When the power is OFF The set parameter is not maintained.
Valid range within items The set parameter is valid until the next valid setting.
Valid range and term of
command
Valid range between items The set parameter is valid until the next valid setting.
[Function]
Registering print format.
[Format]
<YS>,aaa
• Parameter
a [Format registration number] = Valid Range
:
1 to 999
[Coding Example]
<A>
<CC>1
<YS>,1
</N>,3,3
<%>0<V>100<H>200<P>2<L>0101<XM>ABC
<Z>
[Supplementary Explanation]
• When registering multiple formats, Delimit Start of Data Transmission <A> and End of Data
Transmission <Z> with one format.
• Specify Card Slot for Use <CC> prior to this command <YS> by all means.
• Use this command and Registration of Field </N> as a pair.
• Attempts to re-register with registered No., error will occur, and the targeted content will be
printed.
• The error occurs when specifying unused or specifying the slot which the printer is allocated.
[Note]
• Do not turn the printer's power off when accessing to the memory. When the printer power is off
while memory accessing, the data in the accessed media may be corrupted.
• The maximum registration with </N> is 99 fields. (Refer to the customizable print command of
the field registration (ESC+/N) for the commands can be registered.)
• The maximum registration with other than </N> is 50 fields. Refer to the customizable print
command for the commands can be registered.)