EasyManua.ls Logo

SATO CL6NX - [ESC+RU] EPC;TID Return (UHF M6 E) (CL4 NX Only)

SATO CL6NX
756 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
432
[ESC+RU] EPC/TID return (UHF M6e) (CL4NX Only)
Command ESC RU Parameter
Hexadecimal code <1B>
16
<52>
16
<55>
16
,aa
Initial Value aa=00
When turning off the power The set command is not maintained.
Valid range within item The set parameter is valid until the next valid setting.
Valid range and term of
command
Valid range between items The set parameter is valid until the next valid setting.
[Function]
This command is used to return EPC/TID together with the result when data is written to the RFID
tag by the <IP0> command.
[Format]
Return specification : <RU>,aa
Request to return : [DC2]PK
• Parameters
Symbol Parameter name Valid range
aa Identifier 00: Not returned (default
setting)
01: Validate return
Obtain return data by
sending [DC2]PK
Two character fixation
[[DC2]PK return data format (normal)]
[STX]a…a,b,c,d…d[CR][LF][ETX]
[Return data]
Symbol Parameter name Valid range
a Total number of data byte
* This is the total number of bytes after parameter b.
The delimiting comma between parameters a and b,
and the ETX are not included.
Data size from the first write result
status until before [ETX]
Maximum 5 digits
b Write result status 0: Write failure
1: Write success
* Specified in text format
c Error symbol N: No error
E: EPC write error
T: TID read error
A: All errors
* Specified in text format
d EPC/TID return data Refer to "EPC/TID return data"
below.