508
[ESC+RU] IDm return (FeliCa) (CL4NX Only)
Command ESC RU Parameter
Hexadecimal code <1B>
16
<52>
16
<55>
16
,aa
Initial Value 00
When turning off the power The set command is not maintained.
Valid range within item The set parameter is in effect until a new specification is
made.
Valid range and term of
command
Valid range between items The set parameter is in effect until a new specification is
made.
[Function]
Returns the result of RFID tag write using <RK> command together with a 64-digit hexadecimal
numeric sequence as a result of IDm+PMm+ID block.
[Format]
Return specification: <RU>,aa
Request to return: [DC2]PK
• Parameters
Symbol Parameter name Valid range
aa Identifier 00: Not returned (default
setting)
01: Validate return
Obtain return data by
sending [DC2]PK.
Two character fixation
[[DC2]PK return data format (normal)]
[STX]a…a,b,c,d…d[CR][LF][ETX]
[Return data]
Symbol Parameter name Valid range
a Total number of data byte
* This is the total number of bytes after parameter b. The
delimiting comma between parameters a and b, and the
ETX are not included.
Data size from the first write result
status until before [ETX]
Maximum 5 digits
b Write result status 0: Write failure
1: Write success
Note: Specified in text format.
c Error symbol
N:
No error
I: IDm read error
A: All errors
Note: Specified in text format.
d IDm return data Refer to “IDm return data” as
below.