28
[ESC+ID] Job ID Number
ESC ID ParameterHexadecimal code
<1B>
16
<49>
16
<44>
16
aa
aaaaa
Initial value a=<20>
16
When the power is OFF The set parameter is not maintained.
Valid range within items The set parameter is valid until the next valid setting.
Valid range and term of
command
Valid range between items The set command becomes invalid.
[Function]
Specifying job ID number for status return.
[Format]
<ID>aa
<ID>aaaaa
• Parameter
a [Job ID number]
Valid range:
00 to 99 (2 digits)
****** or 00000 to 99999 (5 digits)
[Coding Example]
Job ID number: 01
<A>
<ID>01
<V>200<H>100<P>0<$>B,100,100,6
<$=>SATOPRINTER
<Q>2
<Z>
[Supplementary Explanation]
• When status return is used for interface protocol, the specified job ID number can be set to the
telegraphic status.
• Status can be confirmed by sending status request (ENQ).
• Include this command within items and use between start code <A> and stop code <Z>.
• When Status 5 is used, the valid range of job ID becomes "00000 to 99999" and "*****". If "*****"
is specified, the item will not be managed by Job ID number.
[Note]
• In status return interface protocol, this command becomes valid when status request (ENQ) is
received while printing (QTY≠0, includes at the time of Offline and Error).
• In status return communication protocol, if status request (ENQ) is received when printing is not
in progress (QTY=0, No received data when power is ON), space (20H) will be set to status and
returned.