283
[ESC+BQ] QR Code (Compatible command)
ESC BQ ParameterHexadecimal code
<1B>
16
<42>
16
<51>
16
Manual setup: abcc,
(ddeeff,)g(hhhh)n
Auto setup: abcc,(ddeeff,)gn
Initial value Nil
When the power is OFF The set parameter is not maintained.
Valid range within items The set parameter becomes invalid.
Valid range and term of
command
Valid range between
items
The set parameter becomes invalid.
[Function]
Specifying QR code.
[Format]
[Manual setup]
<BQ>abcc,(ddeeff,)g(hhhh)n
[Auto setup]
<BQ>abcc,(ddeeff,)0n
• Parameter
a [Error correction level]
1 : 7%
High density level (L)
2 : 15%
Standard level (M)
3 : 30%
High reliability level (H)
4 : 15%
High reliability level (Q)
b [Concatenation mode]
0 : Normal mode
1 : Concatenation mode
c [Size of one side of cell]
Valid Range
:
01 to 99 (dot)
e.x.) cc=04
4 dots
4 dots
Feed direction
d [No. of partitions by concatenation mode]
Valid range
:
01 to 16
e [Sequential number partitioned by concatenation mode]
Valid range
:
01 to 16
f [Concatenation mode parity data]
Valid range
:
00 to FF
g [Character mode]
0
:
Auto setup mode
1
:
Number mode
2
:
Alphanumeric mode
3
:
Binary mode
4
:
Kanji mode
h [No. of data]
Valid range : 0001 to 7366 (dot)
n [Print data] = Data