352
[ESC+PO] Offset
ESC PO ParameterHexadecimal code
<1B>
16
<50>
16
<4F>
16
abcc
Initial value a=0, b=+, cc=00
When the power is OFF The set parameter is not maintained.
Valid range within items The set parameter is valid until the next valid setting.
Valid range and term of
command
Valid range between items The set parameter is valid until the next valid setting.
[Function]
Gives offset to media’s stop position on the fly.
[Format]
<PO>abcc
• Parameter
a
[Offset]
0
:
Cutter
1
:
Dispenser
2
:
Tear-off
3
:
Continuous
b
[Offset direction]
+
:
Feed forward
-
:
Backward
c
[Amount of offset] =
Valid range
:
00 to 99 (dot)
[Coding Example]
<A>
<PO>3+08
<Z>
[Supplementary Explanation]
• This command does not need to be set in normal printing.
• Please specify an appropriate value when the printing is off, which is unique for each printer.
Printer will not work properly if you do not specify appropriate value.
Parent topic System Command