30
[ESC+WK] Job Name
ESC WK ParameterHexadecimal code
<1B>
16
<57>
16
<4B>
16
aaaaaaaaaaaaaaaa
Initial value aaaaaaaaaaaaaaaa=<20>
16
When the power is OFF The set parameter is not maintained.
Valid range within items The set parameter is valid until the next valid setting.
Valid range and term of
command
Valid range between items The set command becomes invalid.
[Function]
Specifying job name for status return.
[Format]
<WK>aaaaaaaaaaaaaaaa
• Parameter
a [Job Name] = ASCII code 16-digit, Shift JIS Kanji 8-digit
[Coding Example]
Job name: SATO
<A>
<ID>01
<WK>SATO
<V>200<H>100<P>0<$>B,100,100,6
<$=>SATOPRINTER
<Q>2
<Z>
[Supplementary Explanation]
• When Status 4 is used for interface protocol, specified job name can be set to the telegraphic
status.
• Status can be confirmed sending status request (ENQ).
• Include this command within items and use between start code <A> and stop code <Z>.
• This command can be used in combination with Job ID Number <ID>.
[Note]
• In status return interface protocol, this command becomes valid when status request (ENQ) is
received while printing (QTY≠0, includes at the time of Offline and Error).
• In status return communication protocol, if status request (ENQ) is received when printing is not
in progress (QTY=0, No received data when power is ON), space (20H) will be set to status and
returned.
• When Job ID Number <ID> is used more than twice within the items of <A> and <Z>, the last
specified value becomes valid.
• For more information, refer to the "Interface Specifications".
Parent topic Control command