343
[ESC+~A] Cut Number Unit
ESC ~A ParameterHexadecimal code
<1B>
16
<7E>
16
<41>
16
aaaa
Initial value aaaa=1
When the power is OFF The set parameter is not maintained.
Valid range within items The set parameter is valid until the next valid setting.
Valid range and term of
command
Valid range between
items
The set parameter becomes initial value at the next
item <A>.
[Function]
Cuts labels at a specified interval in a print job.
[Format]
<~A>aaaa
• Parameter
a [Number of labels between each cut] = Valid range : 0 to 9999
[Coding Example]
<A>
<V>100<H>200<P>2<L>0202<XM>ABC
<~A>2
<Q>7
<Z>
ABC
7 pcs
2 pcs
1 label left
Cut Cut Cut
Cut
ABC
ABC
ABC
ABC
ABC
ABC
Feed direction
[Supplementary Explanation]
• Valid only for cutter models.
• If the parameter is not specified by this command <~A>, each label will be cut after being
printed.
• In case the parameter "a" is set to 0, no label will be cut.
• Set this command before <Q> command.
• This command may not be used in combination with other cut commands <~>.
Parent topic System Command