566
[DC2+PK] EPC/TID return request (UHF M6e) (CL4NX Only)
Command DC2 PK Parameter
Hexadecimal code <12>
16
<50>
16
<4B>
16
None
Initial value None
When turning off the power -
Valid range -
Printer operation in
progress
The command cannot be received during the printer
operation. ([NAK] return)
When acquiring label
sensor information
Commands are not accepted while acquiring sensor
information. ([NAK] reply)
Valid range and term of
command
Error Commands can be received even if an error is occurring.
[Function]
Returns the status of RFID tag write by <IP0> command and EPC/TID.
[Format]
[DC2]PK
[[DC2]PK return data format (normal)]
[STX]a…a,b,c,d…d[ETX]
[Return data
Symbol Parameter name Valid range
a Total number of data byte
* This is the total number of
bytes after parameter b. The
delimiting comma between
parameters a and b, and the
ETX are not included.
Data size from the first write result status until before [ETX]
Maximum 5 digits
b Write result status 0: Write failure
1: Write success
* Specified in text format.
c Error symbol
N:
No error
E:
EPC write error
T:
TID read error
A:
All errors
* Specified in text format.
d EPC/TID return data Refer to [EPC/TID return data] as below.
* Specified in text format.