[ESC+CR] Status 5 reply check setting
ESC CR ParameterHexadecimal code
<1B>
16
<43>
16
<52>
16
a(,b)
Initial value a=0
When the power is OFF The set parameter is maintained.
Valid range within items The set parameter is valid until the next valid setting.
Valid range and term of
command
Valid range between items The set command becomes invalid.
[Function]
The BCC check of return and the item number check function are set up of the status 5.
[Format]
<CR>a(,b)
• Parameter
a [BCC check]
     
0 : BCC check disable (initial value)
     
1 : BCC check enable
b [Item number check] = 0 : Not checked(fixed value)(omissible)
[Coding Example]
<A>
<ID>****
<CR>1,0
<Z>
[Supplementary Explanation]
• [item number check] is a fixed value.
• This command cannot be used at the same time the print data.
• Use is possible only during status 5 protocol.
Parent topic Control command