725
Abnormal end when CRC check is enabled
In the event of CRC error (Common in status 3 and status 4)
Receiving/Analysis/Editing
* Printer behavior is defined by key operation or
command. Refer to “CRC error display” for details.
ID number=[05]
Print Qty=50
Job name=[SATO]
CONNECT
This productHOST
Print command (STX to ETX CRC)
CRC abnormal data
Note
Received data is cleared and ACK/NAK is not returned when the received printer data has CRC
error.
In the event of disconnection time-out (Common in status3 and status 4)
Receiving/Analysis/Editing
ID number=[05]
Print Qty=50
Job name=[SATO]
CONNECT
This productHOST
Print command (STX to ETX CRC)
××
Disconnection
or communication failure
Disconnection timeout period has passed.
*Clear print command that has already been received.
Note
In case where receive data is not available in communication time-out period (10 sec) while
receiving print command, time-out occurs to clear print data that has already been received.
(ACK/NAK is not returned)