362
[ESC+TW] Option Waiting Time
ESC TW ParameterHexadecimal code
<1B>
16
<54>
16
<57>
16
aaa
Initial value aaa = 000
When the power is OFF The set parameter is maintained.
Valid range within items The set parameter becomes invalid.
Valid range and term of
command
Valid range between items The set parameter becomes invalid.
[Function]
Specifies waiting time for optional device.
[Format]
<TW>aaa
• Parameter
aaa [Waiting time] = Valid range
:
000, 005 to 200 (unit: 100ms)
[Coding Example] (waiting time = 1.5 seconds)
<A>
<TW>015
<Z>
[Supplementary Explanation]
• This command specifies, in Tear-off mode, the waiting time between print completion and Tear-
off motion.
• The set parameter becomes valid soon after receiving the command and will be retained after
power off.