350
[ESC+E] Auto Line Feed
ESC E ParameterHexadecimal code
<1B>
16
<45>
16
aaa
Initial value Nil
When the power is OFF The set parameter is not maintained.
Valid range within items The set parameter becomes invalid.
Valid range and term of
command
Valid range between items The set parameter becomes invalid.
[Function]
Specifies amount of line spacing and CR (Line feed).
[Format]
<E>aaa
• Parameter
a [line spacing] = valid range
:
0 to 999 dots
[Coding Example]
<A>
<E>10
<V>100<H>200<P>2<L>0304<XM>ABCDE+CR
FGHIJ+CR
<Q>2
<Z>
[Supplementary Explanation]
• When CR (0DH) is specified, linefeed based on line pitch will be performed.
• Rotation command <%> can be used in combination with this command.
• The command <E> may be used in a job and change the line spacing as necessary.
• Specify this command before designating the consecutive print of 1-line.
• Specifying this command executes the line feed regardless of CR/LF deletion setting.
• Performing auto linefeed by the designation of CR (0DH), print start position of linefeed will be
determined based on the pitch specified with <E> and the value specified with Horizontal Print
Position <H> designated after <E>. In case that <H> is specified several times after <E>, return
position by CR (0DH) will be at the end of <H>.