450
Symbol Parameter name Valid range
* Note: Specified in text format
[Format of UID return data ]
“Specify memory” + “:” + “Data” + “Line feed(0DH, 0AH)”
ee:f…f[CR][LF]
[UID return data]
Symbol Parameter name Valid range
e Specify memory UI: UID
f Data Maximum 16 digits
[Return data format (when a command error occurs)]
[NAK]<15>
16
[Exception processing]
Exception conditionParameter name
A value outside the range is specified The specified size and
received size are different
Identifier Command error Invalid receive data
Terminology Description
Command error The data received after a command error is determined is not
considered as a parameter of this command.
Invalid receive data The data corresponding to Byte 2 and thereafter of the identifier is
ignored.
[Coding Sample]
<A>
<RU>,01
<RK>2,D13,4912345678904
<XM>4912345678904
<Z>
[Sample of status reply ]
When [DC2]PK is received using a tag with E0123456789ABCDE of UID.
Write successful (UID read successful)
[STX]25,1,N,UI:E0123456789ABCDE[CR][LF][ETX]
Write successful(UID read fail)
[STX]9,1,U,UI:[CR][LF][ETX]
Write fail(UID write failed)
[STX]9,0,U,UI:[CR][LF][ETX]
[Supplemental explanation]
The write status and UID is returned when [DC2]PK is received after RFID write.