Section 04 ENGINE (2-STROKE)
Subsection 03 (MAGNETO SYSTEM)
Generating Coil
To replace generating coil no. 6:
– Heat the armature plate to 93°C(200°F) around
the screw holes to break the threadlocker bond.
F00D08A
1
1. Heat the armature plate
CAUTION: Protect harness from flame.
– Remove screws.
– Uncrimp and unsolder BLACK/RED wire from
coil.
A25E0QA
1
1. Uncrimp and unsolder wire here
Battery Charging Coil
To replace battery charging coil no. 7:
– Heat the armature plate to 93°C(200°F) around
the screw holes to break the threadlocker bond.
F00D09A
1
1. Heat the armature plate
CAUTION: Protect harness from flame.
– Remove screws.
– Uncrimp and unsolder YELLOW and YELLOW/
BLACK wires from coil.
– Uncrimp and unsolder ground wire (BLACK)
from coil core.
A25E0SA
1
2
1. Uncrimp and unsolder ground wire (BLACK)
2. Uncrimp and unsolder YELLOW and YELLOW/BLACK wires
787 RFI Engines
Magneto Housing Cover
Disconnect water hoses from heat exchanger cov-
er.
Loosen screws no. 11. Remove engine magneto
cover no. 1.