Section 08 ENGINE MANAGEMENT (4-TEC)
Subsection 03 (DIAGNOSTIC PROCEDURES)
4-TEC SYSTEM FAULT CODES CHART
RESPONSIBLE MODULE
FAULT
CODE
INFORMATION
CENTER
MPEM ECM
BEEPER
CODE
WARNING
LIGHT
MESSAGE
DISPLAYED
(info ctr)
FAULT
DETECTED
WHILE ENGINE
NOT RUNNING
FAULT
DETECTED
WHILE ENGINE
RUNNING
LIMP
HOME
MODE
NORMAL
OPERATION
RESUME
WHEN...
P0106
Manifold
atmospheric
pressure sensor
out of range
15 Flash
CHK
ENG
N Y N
Fault is
recovered
Possible cause:
Sensing port dirty or blocked.
Sensor failure or unexpected reading at idle.
Sensor fallen out of housing or leaking inlet.
Service action:
Check system circuits A-12, A-28 and A-40.
Make sure that the sensor housing is correctly inserted into the manifold. Check sensor connector for:
a) 5 volts on pin 1.
b) 0 volt on pin 2.
c) 0 volt on pin 3.
Manifold
atmospheric
pressure sensor
shorted to ground
15 Flash
CHK
ENG
N Y N
Fault is
recovered
P0107
Manifold
barometric
pressure sensor
shorted to ground
15 Flash
CHK
ENG
Y N N
Fault is
recovered
Possible cause:
Sensing port dirty or blocked.
Sensor failure or unexpected reading at idle.
Sensor fallen out of housing or leaking inlet.
Service action:
Check system circuits A-12, A-28 and A-40.
Make sure that the sensor housing is correctly inserted into the manifold.
Check sensor connector for:
a) 5 volts on pin 1.
b) 0 volt on pin 2.
c) 0 volt on pin 3.