Setup Data 5
Setup2 Editor 5.4
248
W+F (tab)
Further information:
Table Tools [-> 244]
File tools [-> 245]
Helpers for Input [-> 239]
Overview of the Setup2 Editor of the CMS [-> 237]
Setup Data [-> 233]
Comparing Setup1 to Setup2 [-> 235]
Explanation Value range
W+F… Auxiliary Take-down function W+F1 - W+F50
W+F On Switch on auxiliary take-down.
The auxiliary take-down will be
closed.
The speed of the auxiliary take-down
W+=n is active
Switch off the auxiliary take-down.
The auxiliary take-down will be
opened.
W+= Input of the speed of the auxiliary
take-down
Turning value n (1-15)
Minimum value: 1
Maximum value: 15
Step width: 1
W+P Contact pressure n (0-10), only for
machines with 72 and 84 inch
working width
Minimum value: 0
Maximum value: 10
Step width: 1
W+C Monitoring of auxiliary take-down. If
the auxiliary take-down has not been
used after n (0-100) knitting rows, the
machine will stop. (0 = no
supervision)
Minimum value: 0
Maximum value: 100
Step width: 1
Comment Comment ASCII Characters