098-00564-000 Revision A3 – July, 2013 TimeProvider 2300/2700 User’s Guide 135
Chapter 3
TimeProvider 2300/2700 CLI Command Set
To provision the PTP priority-2 value for the Master with the Telecom-2008
(unicast) active profile:
set ptp master config eth2 telecom-2008 priority-2
<priority-2-value>
To provision the PTP domain value for the Master with the Telecom-2008
(unicast) active profile:
set ptp master config eth2 telecom-2008 domain
<domain-value>
To provision the PTP Diffserv Code Point value for the Master with the
Telecom-2008 (unicast) active profile:
set ptp master config eth2 telecom-2008 dscp <dscp-value>
To provision the PTP dither value for the Master with the Telecom-2008 (unicast)
active profile:
set ptp master config eth2 telecom-2008 dither {enable |
disable}
To provision the IP Header Time to Live (TTL) field for PTP packets for a Master
with the Telecom-2008 (unicast) active profile:
set ptp master config eth2 telecom-2008 ttl <TTL-value>
To provision the PTP unicast negotiation state for the Master with the
Telecom-2008 (unicast) active profile:
set ptp master config eth2 telecom-2008 unicast-negotiation
{enable | disable}
To set the PTP unicast maximum lease-limit value for the Master with the
Telecom-2008 (unicast) active profile:
set ptp master config eth2 telecom-2008 lease-limit
<limit-value>
To provision the announce limit, the minimum interval (maximum rate) between
PTP announce messages, for the Master with the Telecom-2008 (unicast) active
profile:
set ptp master config eth2 telecom-2008 announce-limit
<announce-limit value>
The interval is 2
z
seconds, where z= <announce-limit-value>.
To provision the synchronization limit, the minimum interval (maximum rate)
between PTP synchronization messages, for the Master with the Telecom-2008
(unicast) active profile:
set ptp master config eth2 telecom-2008 sync-limit
<sync-limit value>
The interval is 2
z
seconds, where z= <sync-limit-value>.