098-00564-000 Revision A3 – July, 2013 TimeProvider 2300/2700 User’s Guide 149
Chapter 3
TimeProvider 2300/2700 CLI Command Set
TP2700>set ptp master config eth2 default priority-1 200
TP2700>set ptp master config eth2 default priority-2 200
TP2700>set ptp master config eth2 default domain 10
TP2700>set ptp master config eth2 default timescale auto
TP2700>set ptp master config eth2 default announce-interval 2
TP2700>set ptp master config eth2 default sync-interval -6
TP2700>set ptp master config eth2 default announce-receipt-timeout 4
TP2700>set ptp master config eth2 default client-timeout 100
Example 7:
To set the active-profile of PTP client in eth1 port as telecom-2008:
TP2700>set ptp client active-profile eth1 telecom-2008
Example 8:
To provision the following attributes of profile telecom-2008 for PTP client in eth1
port:
ptp-state
ttl
dscp
unicast-negotiation
lease-duration
announce-interval
sync-interval
delay-req-interval
announce-receipt-timeout
domain
Refer to Table B-39, Table B-40, and Table B-41 in Appendix B for range and default
values for PTP parameters.
TP2700>set ptp client config eth1 telecom-2008 ptp-state enable