TOMATECH AUTOMATION
press or and the 5th axis feeds negatively or positively, and its feeding stops if the key is
released. The rapid override time-tuning is enabled.
In Manual mode, press key to make the indicator OFF, and the rapid traverse is disabled
and manual feed is executed.
Note 1: If no reference point return is performed after power on, as the rapid traverse switch is
turned on
(rapid indicator ON), the manual feedrate or rapid rate for the traverse is defined by the Bit0 of the
bit
parameter No.012 of thisTAC-1002T system.
Note 2: In Edit/MPG mode, key is inactive.
3.1.3 Speed tune
In Manual mode, press , , to alter the manual feed override which is divided into
16 steps. The relation of the override and the feedrate is as follows table when data
parameter
No.031 is set to 1260:
Feedrate override (%) Feedrate (mm/min)
0 0
10 126
20 252
30 378
40 504
50 630
60 756
70 882
80 1008
90 1134
100 1260
110 1386
120 1512
130 1638
Chapter 3 Manual Operation
211
Operation
Feedrate override (%) Feedrate (mm/min)
140 1764
150 1890
Note : There is about 2% error for the data in the above table.
In the manual rapid traverse, it can press key to alter the rapid override,
and there are 4 steps of F0, 25%, 50%,100% for the override.(F0 is set by data parameter
No.032)
The rapid override is active under the following conditions:
(1) G00 rapid traverse (2) Rapid traverse in canned cycle
(3) Rapid traverse in G28 (4) Manual rapid traverse

Table of Contents