3.2 Other Manual Operations
3.2.1 Spindle CCW, CW, stop control
: In Manual mode, the spindle rotates counterclockwise if pressing this key;
: In Manual mode, the spindle stops if pressing this key;
: In Manual mode, the spindle rotates clockwise if pressing this key.
3.2.2 Spindle jog
: At the moment, the spindle is in JOG state.
Functional description:
Press to enter JOG mode, and the spindle JOG function ON/OFF is executed only when
the spindle is in the state of stop.
In spindle JOG mode, by pressing key, the spindle rotates counterclockwise for jogging;
by pressing key, the spindle rotates clockwise for jogging. The jog time and speed are set
by
data parameter No.108 and No.109 respectively.
When the spindle JOG rotates, is pressed to stop the spindle JOG rotation, the spindle
brake signal is not output when the JOG rotation stops.
K10.4 is set to 1, the spindle JOG is valid in any mode. In Auto or MDI mode, the spindle
is in the
JOG rotation state, the program closes the spindle JOG rotation and the JOG function.
Parameter setting:
PLC parameter K104 1/0: the spindle JOG is valid in any mode/Manual, MPG, Zero return
mode.
Data parameter No.108: spindle JOG time
Data parameter No.109: rotary speed in spindle JOG.
212
Ⅱ Operation
3.2.3 Cooling control
: In Manual mode, press this key, the cooling is switched on/off.
Parameter setting: PLC parameter K10.1 1/0: the spindle lubricating and cooling output
remains/closes in reset.
3.2.4 Lubricating control
Function description:
1. Non-automatic lubricating (DT017 =0)
When PLC DT013=0, it is the lubricating turn output. Pressing the can execute the
output. And the lubricating is cancelled by pressing it again. M32 is to execute lubricating
output, and
M33 is to cancel lubricating output.
When PLC DT013 >1, it is timing lubricating output. Pressing the can execute the output.