TOMATECH AUTOMATION
Bit1 1: Program end sign EOB displayed for “;”
0: Program end sign EOB displayed for “*”
Bit0 1: Prior to machine zero return after power on, manual rapid traverse active
0: Prior to machine zero return after power on, manual rapid traverse inactive
0 1 2 APRS WSFT DOFSI *** EAL *** *** ISOT
Bit7 1: Automatic ABSOLUTE set after reference return,;
0: ABSOLUTE not automatically set after reference return
Bit6 1: Workpiece coordinate offset active, defined by offset No.000
0: Workpiece coordinate offset inactive
Bit5 1: Trial tool setting active
0: Trial tool setting inactive
Bit3 1: Program editing allowed during CNC alarming
374
Volume Connection
0: Program editing unallowed during CNC alarming
Bit0 1: Prior to machine zero return after power on, manual rapid traverse active
0: Prior to machine zero return after power on, manual rapid traverse inactive
0 1 3 *** *** *** HW5 HW4 HWY HWZ HWX
Bit4 1: Coordinates increase in 5th MPG (CCW) rotation
0: Coordinates increase in 5th MPG (CW) rotation
Bit3 1: Coordinates increase in 4th MPG (CCW) rotation
0: Coordinates increase in 4th MPG (CW) rotation
Bit2 1: Coordinates increase in Y MPG (CCW) rotation
0: Coordinates increase in Y MPG (CW) rotation
Bit1 1: Coordinates increase in Z MPG (CCW) rotation
0: Coordinates increase in Z MPG (CW) rotation
Bit0 1: Coordinates increase in X MPG (CCW) rotation
0: Coordinates increase in X MPG (CW) rotation
0 1 4 *** *** *** ZRS5 ZRS4 ZRSY ZRSZ ZRSX
Bit 4, Bit3, Bit2, Bit1, Bit0
1: 5th, 4th, Y, Z, X have the machine zeroes. The system needs to check the deceleration
signal
and zero signal in executing the machine zero return
0: 5th, 4th, Y, Z, X have no machine zeroes. The system does not check the deceleration
signal
and zero signal till it returns to the zero of machine coordinate in executing the machine
zero return
0 1 7 SCRD *** RSCD *** TSD QNI TSL TS1
Bit7 1:Coordinate system is stored before power-off;
0: Coordinate system is not stored before power-off; the default system is set by G54 after
power-on;
Bit5 1: Coordinate system is set by G54 after reset;
0: Coordinate system is not changed after reset;

Table of Contents