TOMATECH AUTOMATION
Command format: G11
Command function: cancel the tool life management data input mode
Programming
L_: tool life data, the specified value
can be time or number of times
according to the different count
N value
Note 1: The tool group numbers specified by P may not be the continuous, but it is better to
gradually
increase the sequence number to easily search the tool group number.
Note 2: The tool life is 0 when the life data L_ is omitted, and the tool mode is 0 (minute) when the
specified
mode N_ is omitted, at the time, the system only counts and doest not alarm for the output.
Note 3: Other commands between G10 L3 and G11 are ignored.
Note 4: Running the tool life preset program (such as O0020) completely clear all previous life
data and
preset the life data according to the program requirements.
Note 5: Prevent the life data from being modified manually when the part programs are running
until the run
state stops (except for running the tool life preset programs).
Note 6: All tool life data is stored when power-down.