7.3 Operation in Parameter Setting Mode (Pn)
7-25
7
Digital Operator/Panel Operator
(3) Allocating Input Signals
The procedure to replace Servo ON (/S-ON) signal allocated to CN1-40 and Forward External Torque Limit (/
P-CL) allocated to CN1-45 is shown below.
EXAMPLE
Pn50B:
Pn50A:
Before After
Step
Display after
Operation
Digital
Operator
Panel Operator Description
1
Press the DSPL/SET or MODE/SET Key to select the
“value setting parameter” mode. If a parameter other
than Pn50A is displayed, press the UP or DOWN Key to
set Pn50A.
Note: The enabled digit blinks.
2
Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second to display the current data
of Pn50A.
(/S-ON is allocated to CN1-40.)
3
Press the UP Key to set to “1.”
(Sequence input signals can be freely set.)
4
Press the LEFT or RIGHT Key or DATA/SHIFT Key to
select the second digit from the right. Press the UP key
to set to “5.”
(Changes the allocation of /S-ON from CN1-40 to CN1-
45.)
5
Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second. The value blinks and is
saved.
At the moment, the CN1-45 operates with OR logic for
/S-ON and /P-CL.
6
Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second to return to the display
Pn50A.
7
Press the UP Key to set Pn50B.
Note: The enabled digit blinks.
8
Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second to display the current data
of Pn50B.
(/P-CL is allocated to CN1-45.)
9
Press the LEFT or RIGHT Key or DATA/SHIFT Key to
select the third digit from the right. Press the DOWN
Key to set to “0.”
(Changes the allocation of /P-CL from CN1-45 to CN1-
40.)
10
Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second. The value blinks and is
saved.
11
Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second to return to the display
Pn50B. /S-ON is allocation to CN1-45, and /P-CL is
allocated to CN1-40.
12 Turn the power OFF and ON again to enable the change of input signal selections (Pn50A and Pn50B).
DSPL
SET
(DSPL/SET Key)
MODE/SET
(MODE/SET Key)
DATA
ENTER
(DATA/ENTER
K
ey)
DATA
(DATA/SHIFT Key)
(Press at least 1 s.)
(UP Key)
(UP Key)
DATA/
(DATA/SHIFT Key)
DATA
ENTER
(DATA/ENTER
K
ey)
DATA
(DATA/SHIFT Key)
(Press at least 1 s.)
DATA
ENTER
(DATA/ENTER
K
ey)
DATA
(DATA/SHIFT Key)
(Press at least 1 s.)
(UP Key)
(UP Key)
DATA
ENTER
(DATA/ENTER
K
ey)
DATA
(DATA/SHIFT Key)
(Press at least 1 s.)
DATA/
(DATA/SHIFT Key)
DATA
ENTER
(DATA/ENTER
K
ey)
DATA
(DATA/SHIFT Key)
(Press at least 1 s.)
DATA
ENTER
(DATA/ENTER
K
ey)
DATA/
(DATA/SHIFT Key)
(Press at least 1 s.)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Sigma II Series and is the answer not in the manual?

YASKAWA Sigma II Series Specifications

General IconGeneral
BrandYASKAWA
ModelSigma II Series
CategoryController
LanguageEnglish

Related product manuals