8.4 Absolute Encoders
8-35
8
Operation
Final absolute data P
M
is calculated by following formula.
(3) Detailed Signal Specifications
(a) PAO Serial Data Specifications
The number of revolutions is output in five digits.
Note: 1. Data is “P+00000” (CR) or “P-00000” (CR) when the number of revolutions is zero.
2. The revolution range is “+32767” to “-32768.” When this range is exceeded, the data changes from
“+32767” to “-32678” or from “-32678” to “+32767.” When changing multiturn limit, the range
changes. For details, refer to 8.4.7 Multiturn Limit Setting.
P
E
Current value read by encoder
P
E
= M × R + P
O
P
M
= P
E
- P
S
M Multiturn data (rotation count data)
P
O
Number of initial incremental pulses
Use the following for reverse rotation
mode (Pn000.0 = 1).
P
E
= -M × R + P
O
P
M
= P
E
- P
S
P
S
Absolute data read at setup (This is saved and controlled by the host
controller.)
P
S
= M
S
×
R + P
S
'
M
s
Multiturn data read at setup
P
S
' Number of initial incremental pulses read at setup
P
M
Current value required for the users system
R Number of pulses per encoder revolution (pulse count after dividing,
value of Pn201)
Coordinate
value
Value M
Reference position (setup)
-1 0 +1 +2 +3
+3
Current position
+2+1
0
P
E
P
M
P
S
P
O
M×R
Data Transfer Method Start-stop Synchronization (ASYNC)
Baud rate 9600 bps
Start bits 1 bit
Stop bits 1 bit
Parity Even
Character code ASCII 7-bit code
Data format 8 characters, as shown below.
Data
Start bit
Even parity
"+"
or
"- "
"0"
to
"9"
"CR"
"P"
Stop bit
00000 1010 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Sigma II Series and is the answer not in the manual?

YASKAWA Sigma II Series Specifications

General IconGeneral
BrandYASKAWA
ModelSigma II Series
CategoryController
LanguageEnglish

Related product manuals