Configuring BPDU Cop Introduction
4-95
Software Reference for SwitchBlade x3100 Series Switches (Layer Two Switching)
6
SHOW ALARM
(output omitted)
--- Interface(Port) Alarms ---
Interface Fault Severity Time Stamp
------------ ------------------------------- -------- ------------
0.1 Loss of Link Major 17:55:07 05/21
0.21 Loss of Link Major 17:55:07 05/21
0.23 Unexpected BPDU Received Major 10:11:19 05/25
Once the loop is removed, the interface is re-enabled, the fault clears, and traffic resumes after the 10-minute time-out.
Change the TIMEOUT values to 0. With the interface and BPDU Cop enabled, this change is immediate.
7
SET STP INTERFACE=0.23 TIMEOUT=0
If a loop occurs, BPDU Cop disables the interface and it remains disabled.
8
SHOW INTERFACE=0.23
--- GE Interfaces ---
Interface.......................... 0.23
Type............................... GE
State.............................. UP-DN-AutoDisabled
Description........................ <none>
Remote ID.......................... <none>
External Profile................... <none>
Card Type.......................... GE24SFP
Interface Faults
Unexpected BPDU Received........ Major
Manually re-enable the interface
9
DISABLE INTERFACE=0.23 FORCE
Info (039512): Operation Successful (GE24SFP Slot 0 Port 23)
ENABLE INTERFACE=0.23
Info (039512): Operation Successful (GE24SFP Slot 0 Port 23)
SHOW INTERFACE=0.23
--- GE Interfaces ---
Interface.......................... 0.23
Type............................... GE
State.............................. UP-UP-Online
(output omitted)
TABLE 4-15 Configuration Procedure for BPDU Cop
Step Command Description (Optional)