Introduction EPSR and (R)STP Interaction
Software Reference for SwitchBlade x3100 Series Switches (Layer Two Switching)
4-150
ADD EPSR INTERFACE
Description Adds an Interface to the already existing EPSR domain. Only one interface can be speci-
fied at a time when the EPSR domain is of 'Master' node type. If it's a 'Transit' node type
then the user can specify two interfaces at a time. (More than two interfaces are not
allowed in any case.)
Syntax
ADD EPSR=epsrdomain
INTERFACE={ type:id-range | id-range | ifname-list }
[ TYPE={ PRIMARY | SECONDARY } ]
[ PRIORITY=0..127 ]
Options The following table gives the range of values for each option that can be specified with
this command and a Default Value (if applicable).
Example
ADD EPSR=allied-1 INTERFACE=ETH:[8.2]
Option Description Default Value
EPSR The domain name of the EPSR.
INTERFACE The Ethernet interface that is being configured as
part of the EPSR.
NA
TYPE For a system that is being designated as the Master
Node, whether the interface will be a PRIMARY
PORT (PP) or Secondary port (SP)
SECONDARY
PRIORITY Sets the ring port priority for a domain when the
ring port is part of a common link spanning one or
more superloop segments. Refer to 4.6.10.
0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis SwitchBlade x3100 Series and is the answer not in the manual?

Allied Telesis SwitchBlade x3100 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelSwitchBlade x3100 Series
CategorySwitch
LanguageEnglish

Related product manuals