Password Recovery Introduction
1-43
Software Reference for SwitchBlade x3100 Series Switches (Setting Up the Switch)
RESET USER (SEC)
Syntax
RESET USER[=login-name] [COUNTER[={ALL|GLOBAL|USER}]]
Description Resets the User Authentication Database counters for one or all users, or resets global
counters for the User Authentication Facility. Statistics about users are shown with the
SHOW USER and SHOW SYSTEM USERCONFIG commands. The login name is not
case sensitive.
Options The following table gives the range of values for each option that can be specified with
this command and a default value (if applicable).
Example RESET USER COUNTER=ALL
Option Description Default Value
USER If a login name is specified with the USER parameter, the
COUNTER parameter is optional (only USER may be
specified) and the activity counters for the specified user
are reset.
COUNTER If a login name is not specified with the USER parameter
then the COUNTER parameter is used to specify which
counters should be reset. If USER is specified, the activ-
ity counters for all users are reset.
If GLOBAL is specified, the global counters for the User
Authentication Facility are reset.
If ALL is specified, all counters are reset.
USER