Configuring an SNMP Community Introduction
7-61
Software Reference for SwitchBlade x3100 Series Switches (Network Management)
DISABLE SNMP AUTHENTICATE_TRAP (SEC)
Syntax
DISABLE SNMP AUTHENTICATE_TRAP
Description The DISABLE SNMP AUTHENTICATE_TRAP command disables the generation of
authentication failure traps by the SNMP agent. The following authentication failure traps
are suppressed:
- Invalid community used to access the device.
- Invalid use of community (Attempting a SET with a READ-ONLY community.
- Invalid access from a MANAGER that is not a "trusted" host or is not associated with
the community associated with the SNMP operation. An authentication failure trap is not
generated if the community is set with OPEN=true. (See CREATE SNMP COMMUNITY
or SET SNMP COMMUNITY).
Options N/A
Example DISABLE SNMP AUTHENTICATE_TRAP