Introduction Configurable Alarm Severity (Interface Alarm)
Software Reference for SwitchBlade x3100 Series Switches (Alarms and Troubleshooting)
8-8
SET ALARMS THRESHOLD
Syntax
SET ALARMS THRESHOLD [ MINOR=value ] [ MAJOR=value ] [ CRITI-
CAL=value ]
Description The alarm thresholds control when the MINOR, MAJOR, and CRITICAL Port Outage
Threshold alarms are raised. The entered values must be non-zero and satisfy the condi-
tion: MINOR < MAJOR < CRITICAL These signify the lowest number of ports for that
alarm to be raised. When all UPLINK ports are out of service a CRITICAL alarm will be
raised regardless of the threshold values.
Options The following table gives the range of values for each option that can be specified with
this command and a default value (if applicable).
Example
SET ALARMS THRESHOLD MINOR=10
Warning(033613): 9 ports can go out of service before
an alarm is raised if the MINOR threshold is 10.
Threshold Mark
--------------------------------------
MINOR 10
MAJOR 24
CRITICAL 128
Info (010017): Operation Successful
Option Description Default Value
THRESH-
OLD
MINOR - Minimum number of ports before a MINOR
alarm is raised. Setting minor to anything greater than 1
is allowed but not recommended. That means that
(MINOR - 1) ports can be out of service before the
threshold alarm is raised.
MAJOR - Minimum number of ports before a MAJOR
alarm is raised.
CRITICAL - Minimum number of ports before a CRITI-
CAL alarm is raised.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis SwitchBlade x3100 Series and is the answer not in the manual?

Allied Telesis SwitchBlade x3100 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelSwitchBlade x3100 Series
CategorySwitch
LanguageEnglish

Related product manuals