EasyManua.ls Logo

D-Link DGS-1100-06/ME - Create Authen_Login Method_List_Name; Config Authen_Login

D-Link DGS-1100-06/ME
275 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DGS-1100-06/ME Metro Ethernet Managed Switch CLI Reference Guide
214
Command
Parameter
server_group
config authen
server_group
[<string 15> | radius] [add | delete] server_host [<ipaddr> | ipv6address
<ipv6addr>] protocol radius
delete authen
server_group
<string 15>
show authen
server_group
{<string 15>}
enable admin
config admin
local_enable
Each command is listed in detail, as follows:
create authen_login method_list_name
Purpose
To create a user-defined list of authentication methods for users
logging on to the Switch.
Syntax
create authen_login method_list_name <string 15>
Description
The create authen_login method_list_name command creates a
list of authentication techniques for user login. The Switch can
support up to eight method lists, but one is reserved as a default and
cannot be deleted. Multiple method lists must be created and
configured separately.
Parameters
<string 15> - Defines the method_list_name to be created as a string
of up to 15 alphanumeric characters.
Restrictions
Only Administrator or operator-level users can issue this command.
Example usage:
To create the method list Trinity:
DGS-1100-06/ME:5#create authen_login method_list_name Trinity
Command: create authen_login method_list_name Trinity
Success.
DGS-1100-06/ME:5#
config authen_login
Purpose
To configure a user-defined or default method list of authentication
methods for user login.
Syntax
config authen_login [default | method_list_name <string 15>]
method [radius | local | server_group <string 15> | none]
Description
The config authen_login command configures a user-defined or
default method list of authentication methods for users logging on to
the Switch. The sequence of methods implemented in this command

Table of Contents