DGS-1100-06/ME Metro Ethernet Managed Switch CLI Reference Guide
39
the global state configuration of the PPPoE circuit ID insertion
function.
Parameters
None.
Restrictions
None.
Example usage:
To view the global PPPoE ID insertion state:
DGS-1100-06/ME:5#show pppoe circuit_id_insertion
Command: show pppoe circuit_id_insertion
Status: Enabled
DGS-1100-06/ME:5#
show pppoe circuit_id_insertion ports
Purpose
Used to display the PPPoE ID insertion configuration on a per
port basis.
Syntax
show pppoe circuit_id_insertion ports {<portlist>}
Description
The show pppoe circuit_id_insertion ports command allows
the user to view the configuration of PPPoE ID insertion for each
port.
Parameters
<portlist> - Specifies which ports to display. If no ports are
specified, all ports configuration will be listed.
Restrictions
None.
Example usage:
To view the PPPoE circuit ID configuration for ports 2 to 5:
DGS-1100-06/ME:5#show pppoe circuit_id_insertion ports 2-5
Command: show pppoe circuit_id_insertion ports 2-5
Port State Cirucit ID
---- -------- -------------------------------------
2 Enabled Switch MAC
3 Enabled Switch MAC
4 Enabled Switch MAC
5 Enabled Switch MAC
DGS-1100-06/ME:5#