To configure the command prompt.
config command_prompt [<string 32> | default | username]
The config command_prompt command configures the command
prompt.
<string 32> – The command prompt can be changed by entering a
new name of no more that 32 characters.
default – The command prompt will reset to factory default command
prompt. Default = the name of the Switch model, for example “DGS-
1100-06/ME”.
username – The command prompt will be changed to the login
username.
Only Administrator-level users can issue this command. Other
restrictions include:
If the “reset” command is executed, the modified command prompt
will remain modified. However, the “reset config/reset system”
command will reset the command prompt to the original factory
banner.
Example usage:
To modify the command prompt to “AtYourService”:
DGS-1100-06/ME:5#config command_prompt AtYourService
Command: config command_prompt AtYourService
Success.