EasyManua.ls Logo

Ericsson iPECS-100 - Page 457

Ericsson iPECS-100
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iPECS-LIK
Feature Description & Operation Manual
Issue 6.1
412
2. Unregister VMEX
SIP Data / PGM 215
check a station or stations and implement delete button operation
When a station is unregistered from VMEX it goes to Out Of Service state
automatically.
To activate the station for other user, you can replace type and MAC and force
‘Service state by click ‘STA, check ‘SVC and save in PGM103.
Also, you can replace that station automatically by station login with ID/PWD table in
PGM 443. In PGM 443, just input same station number as the deactivated station
and that will be activated automatically.
3. VMEX attributes
SIP Data / PGM 215
1) Station Number : you can change station number and this is same as you
do in PGM 105
2) Mobile Number
a incoming CLI from remote Mobile Phone : address of SIP From’ message
header
This is ID of SIP Extension.
With this CLI the Mobile is identified as an extension
3) Connection Table
Outgoing destination address to Mobile Phone
Connection IP information of Mobile Phone
index of connection table
4) Failover
Failover information
PGM 236 Mobile Extension Table
Usage : Fail Over
CO Group : a public CO
Telephone Number : a public telephone number
c.f) currently, I have a thing to do more.
In this version, failover is implemented when receive 408 time out message
from SIP stack. You should wait somewhat long time to meet 408 time out
message after dial the VMEX. And there is no ringback tone when failover is
tried.
I will add failover time in PGM 211 per stations and will modify for ringback
tone serve. This failover is not only for VMEX but also for all of SIP extensions.

Table of Contents