EasyManua.ls Logo

Fujitsu PRIMERGY RX1330 M3

Fujitsu PRIMERGY RX1330 M3
342 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RX1330 M3 Upgrade and Maintenance Manual 147
Hard disk drive (HDD) / solid state drive (SSD)
7.2.6 Removing 2.5-inch HDD/SSD modules
7.2.6.1 Preliminary steps
Ê If the HDD/SSD module to be removed is combined into a RAID array,
please proceed as follows:
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V CAUTION!
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array! Be sure to back up your data before deleting a RAID
array.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools: tool-less
RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0 array if
defective.
V CAUTION!
Removing an operational HDD module will result
in data loss!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5 array
will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I After replacing the HDD module, RAID rebuild will
be performed as a background process as
described in section "Performing a RAID array
rebuild" on page 96.

Table of Contents

Other manuals for Fujitsu PRIMERGY RX1330 M3

Related product manuals