RX1330 M3 Upgrade and Maintenance Manual 341
Appendix
16.4 Minimum startup configuration
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Ê "Shutting down the server" on page 53
Ê "Disconnecting the power cord" on page 54
Ê Take the system down to its minimum startup configuration.
Ê "Connecting the power cord" on page 64
Ê Connect a keyboard, mouse and display to the server.
Ê "Switching on the server" on page 66.
Field Replaceable Units (FRU)
Component Notes
System board no TPM, UFM or expansion cards installed
CPU with heat sink
1 memory module installed in DIMM slot 1A
Front panel module
PSU
Table 6: Minimum startup configuration - components
Cable Notes
Front panel cable
Power cable
Table 7: Minimum startup configuration - cables