RX1330 M3 Upgrade and Maintenance Manual 257
13 Front panel
Safety notes
V CAUTION!
● When inserting the front panel into the server, ensure not to pinch or
strain any connected cables.
● Circuit boards and soldered parts of internal options are exposed and
can be damaged by static electricity. Always discharge static build-up
(e.g. by touching a grounded object) before handling electrostatic-
sensitive devices (ESDs).
● Do not touch the circuitry on boards or soldered parts. Hold circuit
boards by their metallic areas or edges.
● For further information, please refer to chapter "Important
information" on page 35.
13.1 Basic information
In case of a defective ambient temperature sensor, please replace the front
panel.
Front panel module
The front panel module consists of a holder and a front panel board. These
components are already pre-assembled. The USB connector of the front USB
cable must be installed in the dependant recesses of the holder. As an option
the holder can be equipped with a front VGA connector.
Front panel on QRL (10 x 2.5-inch HDD configuration)
The front panel on QRL (Quick Release Lever) is only available for the servers
with a 10 x 2.5-inch HDD configuration. The front panel is mounted on the right
QRL. A flat cable is used for connection to the system board.