RX1330 M3 Upgrade and Maintenance Manual 51
Basic hardware procedures
Software / agent related errors:
Check the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
I For further information, please refer to the "ServerView System
Monitor" user guide.
4.1.2.2 Customer Self Service (CSS) indicator
Ê Check the CSS indicator on the front panel of the server.
Ê For further diagnostics, proceed as follows:
Hardware errors:
Check the System Event Log (SEL) as described in section "Viewing the
SEL" on page 92.
Software / agent related errors:
Check the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
I For further information, please refer to the "ServerView System
Monitor" user guide.
4.1.3 Locating the defective component
After determining the error class by the CSS or Global Error indicators (see
section "Determining the error class" on page 50) local diagnostic indicators on
the system board, HDD modules and PSUs (only slide-in units) allow you to
identify the defective component.
I For further information, refer to the "ServerView Suite Local Service
Concept (LSC)" manual.
4.1.3.1 Local diagnostic indicators on the front
Ê Check the CSS indicator (see section "Connectors and indicators" on
page 324) on the front panel or connector panel of the server.
I In addition to local diagnostic indicators, CSS or Global Error LEDs
indicate, if the defective component is a customer or field replaceable
unit.