RX1330 M3 Upgrade and Maintenance Manual 241
Processor (CPU)
11.2.7 Concluding steps
Ê "Reassembling" on page 60
Ê "Connecting the power cord" on page 64
Ê "Switching on the server" on page 66
I When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the error
message CPU has been changed. This only indicates that the CPU
configuration has been altered. There is no technical problem.
In order to turn off the Global Error indicator, please proceed as
follows:
Ê Restart the system and wait for screen output to appear.
Ê Press the [F2] function key to enter the BIOS.
If assigned, enter the BIOS password and press [Enter].
Ê In the Save & Exit menu, select Save Changes and Exit or Save
Changes and Reset.
Ê Ensure that the Global Error indicator has stopped flashing.
Ê If applicable, "Updating or recovering the system board BIOS and iRMC" on
page 79
Ê "Resetting the error status after replacing memory modules or CPUs" on
page 86
Ê "Enabling replaced components in the system BIOS" on page 90
Ê "Resuming BitLocker functionality" on page 95