RX1330 M3 Upgrade and Maintenance Manual 333
Appendix
Indicators on the hot-plug HDD module
Figure 241: Indicators on the hot-plug HDD module
Pos. Label Indicator Status Description
1
Access
indicator
off
The HDD is inactive.
green on The HDD is being accessed.
2
Error
indicator
off No HDD error detected.
orange on
An HDD error has been detected.
Possible causes:
The drive is defective and needs
replacing.
A RAID rebuild process has
failed.
The HDD/SSD module has not
been inserted correctly.
orange
flashing
slowly
HDD RAID rebuild is in progress.
Data is being restored after
replacing a drive that has been
combined into a RAID array.
!

Table of Contents