Upgrade and Maintenance Manual 113
Hard disk drives / solid state drives
7.2.4 Concluding steps
Ê "Performing a RAID array rebuild" on page 84
7.3 Removing a 2.5-inch HDD/SSD module
V Only applicable for removing non-defective HDD/SSD modules:
Ê Set the drive to "Offline" via the software (RAID controller
configuration software), before removing an HDD/SSD module that is
not defective.
7.3.1 Preliminary steps
Ê Ensure that the HDD/SSD module to be removed is not combined into a
RAID array. If the drive is part of a RAID array, you first need to delete the
array using ServerView RAID Manager.
V CAUTION!
All data on all HDDs/SSDs in the array will be lost! Be sure to back up
your data before deleting a RAID array.
I For further information, please refer to the "ServerView Suite RAID
Management" user guide.