RX200 S8
Upgrade and Maintenance Manual 335
Appendix
17.4 Minimum startup configuration
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Jumper Status Description
CN101
3-5 position: Normal operation (default)
Password Clear and Recovery BIOS
disabled
1-2 position: Password Clear enabled
5-6 position: Recovery BIOS enabled
J9
1-2 position: Normal operation (default)
2-3 position: Clear CMOS data and restore
default settings
Field Replaceable Units (FRU)
Component Notes
System board no TPM, UFM or expansion cards installed
CPU with CPU heat sink installed in socket CPU 1
1 memory module installed in slot DIMM 1A
Front panel module
Power supply unit installed in bay 1
Table 6: Minimum startup configuration - components