124 Upgrade and Maintenance Manual
RX200 S8
Hard disk drives / solid state drives
Figure 54: Installing the fan cage
Ê Insert the fan cage (1).
Ê Push the fan cage somewhat in direction of the arrow (2) to engage the
hooks (see close-up).
Ê Fasten fan cage with the four screws (3).
Ê Install all fan modules as described in section "Installing the new fan module"
on page 134.
I Make sure that you reinstall the fan module in the bay it was located
before the 8xHDD backplane replacement.
Ê Connect the cables to the 8xHDD backplane as shown in figure 49.
Ê Insert all HDD/SSD modules, see section "Installing the 2.5-inch HDD/SSD
module" on page 112.
I Make sure that you reinstall the HDD/SSD module in the bay it was
located before the 8xHDD backplane replacement.
7.6.4 Concluding steps
Ê "Installing the air duct" on page 62
Ê "Reassembling" on page 52
Ê "Connecting the server to the mains" on page 57
Ê "Switching on the server" on page 58