Upgrade and Maintenance Manual 57
Basic hardware procedures
4.6 Connecting the server to the mains
V CAUTION!
The server supports a mains voltage in the range of 100 V - 240 V. You
may only operate the server if its rated voltage range corresponds to the
local mains voltage.
Ê Connect all power cords to the power outlets.
I To provide true phase redundancy, the second power supply unit
should be connected to a different AC power source from the other
power supply unit. If one AC power source should fail, the server will
still continue to run.
I After connecting the server to the mains it takes about 60 secondes
until the server enters the standby mode.
Ê Ensure that the indicator on the power supply unit lights up green.
I For more information see section "Indicators on power supply units"
on page 331.
Figure 12: Locking the cable clamp of a power supply unit
Ê Pull the cable clamp up (1).
Ê Thread the power cord through the cable clamp (2).
Ê Press the cable clamp down until it engages to secure the cable (3).