222 Upgrade and Maintenance Manual
RX200 S8
Processors
Ê "Updating or recovering the system board BIOS and iRMC" on page 70
Ê "Enabling SVOM boot watchdog functionality" on page 78
Ê "Switching on the server" on page 58
Ê "Enabling BitLocker functionality" on page 83
11.3 Replacing a processor
V CAUTION!
Processors are modules which are extremely sensitive to electrostatic
discharges and therefore must always be handled with care. After a
processor has been removed from its protective sleeve or from its
socket, place it with its smooth side down on a non-conducting, antistatic
surface. Never push a processor over a surface.
11.3.1 Preliminary steps
Ê "Locating the defective server" on page 43
Ê "Disabling SVOM boot watchdog functionality" on page 64
Ê "Disabling BitLocker functionality" on page 63
Ê "Shutting down the server" on page 46
Ê "Disconnecting the server from the mains" on page 47
Ê "Getting access to the component" on page 47
Ê "Removing the air duct" on page 62
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Software: 5 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver

Table of Contents

Other manuals for Fujitsu PRIMERGY RX200 S8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX200 S8 and is the answer not in the manual?

Fujitsu PRIMERGY RX200 S8 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX200 S8
CategoryServer
LanguageEnglish

Related product manuals